Works
AIR-CONDITIONERS INNER MACHINE CHEMICAL WASH
-
Ceiling cassette built-in type machine. Before operation.
-
After took off the machine FACE.
-
After took off the drain pan.
-
Status quo of the heat exchanger fin and coil.
-
Set up the Plastic hopper.
-
Spray the Chemical and water to the heat exchanger fin and coil in the Plastic hopper. It like the dirt coating.
-
After spraied the Chemical and water to the heat exchanger fin and coil. The dirt was removed.
-
Wash by the high-pressure water. Wash dirt and the chemical by the strong pressure water.
-
After the chemical wash. It can save the electric power fee over 15%.
-
After the chemical wash, the hopper got the dirt in the bucket.
-
After the chemical wash, the hopper got the dirt in the bucket.
-
After the chemical wash. Restoration work.
Inner PAC(Package Air Conditioner) Chemical cleaning
We suggest it for 3 reasons.
①To keep the room air fin clean.
②Clean keep heat-exchange fin & coil gives the cold air passing through easily.
※ You can save the electric power fee over 15%.
③Not only the electric power fee, it can save the compressor in the out side machine of PAC
If you continue to use without cleaning, the compressor must work in the heavy load situation.
To replace the compressor is the expensive repairing.